Technical Support & Engineering Services background

Technical Support & Engineering Services

Comprehensive rack safety inspections, seismic audits, upright repairs, and structural maintenance for industrial warehouses across Ecuador.

EN 15635 & ANSI AuditsCertified rack safety & structural health inspections
Seismic ComplianceRecertification aligned with NEC-SE-DS standards
Rapid On-Site CrewsGuayaquil, Quito & nationwide field technicians
OEM Spare ComponentsGuaranteed compatibility & certified steel quality
Engineering Care

Comprehensive Technical Support for Storage Infrastructure

At Ecuador Heavy Shelving Solutions S.A., we ensure your material handling systems operate safely, meet international structural standards, and maintain full operational efficiency throughout their lifecycle.

Rack Safety Audits & Inspections

Periodic racking inspections conducted by structural engineers according to European Standard EN 15635 and ANSI MH16.1 specifications. We identify component deformations, beam locks, and floor anchorage integrity.

  • Green, Amber, and Red risk level categorisation
  • Detailed photographic inspection reports
  • Official load plaque issuing & compliance certificates

Seismic Verification & Load Certification

Ecuador’s geography requires precise seismic engineering calculations. Our technical team evaluates existing pallet racking setups against local seismic standards (NEC-SE-DS) and verifies concrete slab load capacity.

  • Dynamic seismic bracing & frame stability verification
  • Concrete floor slab anchor pull-out load testing
  • Load table recalibration following operational changes

Preventative Maintenance & Upright Repairs

Forklift impacts can severely weaken vertical uprights. We supply quick-turnaround replacement profiles, post protectors, and structural reinforcement systems to prevent rack collapse without full system teardown.

  • Immediate replacement of damaged frames and beams
  • Heavy-duty column guard & row protector installation
  • Scheduled quarterly & annual maintenance agreements

System Relocation & Reconfiguration

When expanding operations or moving to new warehouse space in Guayaquil, Quito, or Cuenca, our field teams manage teardown, transport, re-erection, and structural alignment with zero risk.

  • Safe disassembly and inventory tracking
  • Re-engineering layouts to optimize new clear heights
  • Laser-guided plumb leveling & anchor re-installation
Standard Process

Our Technical Support & Audit Workflow

A systematic, engineering-led approach to maintaining structural reliability and worker safety across all facility types.

01

Initial Request

Submit layout plans, photo evidence of damage, or inspection requests directly to our engineering desk.

02

Site Assessment

Certified engineers inspect uprights, beams, anchors, and slab stability on site in any Ecuadorian province.

03

Report & Planning

Receive a clear audit report detailing hazard levels, required parts, seismic checks, and remediation steps.

04

Execution & Signoff

Certified field crews execute repairs or upgrades, issuing updated load plaque documentation upon completion.

Service Level SLA Commitment

Ecuador Heavy Shelving Solutions S.A. provides structured Service Level Agreements (SLAs) tailored to high-throughput distribution centers and cold storage facilities.

  • Rapid dispatch for critical Red-Risk structural damage
  • Dedicated OEM spare parts inventory reservations
  • Bilingual technical reports for overseas corporate compliance

Need Immediate Engineering Support?

Send structural drawings, damaged component photos, or project details to our dedicated support desk:

[email protected]

Support FAQ

Technical Support & Inspections FAQ

Answers to common questions from warehouse managers, safety officers, and international buyers operating in Ecuador.

Require Custom Engineering Documentation?

We provide full structural calculations, seismic reports, and localized certification documents for industrial audits.

[email protected]
How often should pallet racking be inspected in Ecuador?
In accordance with EN 15635 guidelines, industrial pallet racking systems should undergo visual inspections weekly by internal warehouse personnel and a formal structural audit by a qualified technical engineer at least once every 12 months, or immediately following any significant forklift impact or seismic event.
What occurs during a seismic rack evaluation?
Our engineers evaluate the facility's location according to NEC-SE-DS seismic zones, calculating upright frame capacity, bracing strength, baseplate dimensions, and anchor bolt embedded depth into the concrete slab to ensure stability during seismic ground motion.
Can damaged rack uprights be repaired instead of fully replaced?
Depending on the severity (classified under Green, Amber, or Red risk levels), minor deformations can be reinforced using certified upright repair sleeves or individual frame component replacements without tearing down the entire bay.
Are replacement components compatible with existing racking brands?
We carry standardized cold-rolled steel profiles compatible with major international rack configurations. During our technical assessment, we verify geometry, steel grade, and load dynamics before supplying replacement parts.

Request Technical Support or Schedule an Inspection

Connect directly with our engineering team to ensure your storage systems are safe, compliant, and operating at peak performance.

Contact Us